2. Context
Author1 Parzianello, Luiz Claúdio
2 Furuie, Sérgio Shiguemi
3 Moura, Lincoln
Affiliation1 Divisão de Informática do Instituto do Coração de São Paulo (InCor)
2 Divisão de Informática do Instituto do Coração de São Paulo (InCor)
3 Divisão de Informática do Instituto do Coração de São Paulo (InCor)
EditorLotufo, Roberto de Alencar
Mascarenhas, Nelson Delfino d'Ávila
e-Mail Addresscintiagraziele.silva@gmail.com
Conference NameSimpósio Brasileiro de Computação Gráfica e Processamento de Imagens, 8 (SIBGRAPI)
Conference LocationSão Carlos, SP, Brazil
Date25-27 Oct. 1995
PublisherSociedade Brasileira de Computação
Publisher CityPorto Alegre
Pages257-263
Book TitleAnais
Tertiary TypeArtigo
History (UTC)2013-02-18 16:37:07 :: cintiagraziele.silva@gmail.com -> administrator ::
2022-06-17 21:39:34 :: administrator -> cintiagraziele.silva@gmail.com :: 1995
3. Content and structure
Is the master or a copy?is the master
Content Stagecompleted
Transferable1
Keywordsimage processing
medical imaging
AbstractWe present a method for automatic detection of left ventricle (LV) contour in gated blood pool studies based on G operator, used as an enhancing filter. The LV is localized automatically in the diastolic frame using a fuzzy membership function of localization over the filtered image. After that, the LV contour is searched by a region growing algorithm with constraints in the diastolic frame. In the other frames, contours are detected via heuristic local search using the previously detected contour as a template and looking for an optimal path.
TypeImagens Médicas
Arrangement 1urlib.net > SDLA > Fonds > Full Index > Automated detection of...
Arrangement 2urlib.net > SDLA > Fonds > SIBGRAPI 1995 > Sumário > Automated detection of...
Arrangement 3urlib.net > SDLA > Fonds > SIBGRAPI 1995 > Sumário > Índice > Automated detection of...
doc Directory Contentaccess
source Directory Contentthere are no files
agreement Directory Contentthere are no files
4. Conditions of access and use
data URLhttp://urlib.net/ibi/8JMKD3MGPBW34M/3DJCJ9H
zipped data URLhttp://urlib.net/zip/8JMKD3MGPBW34M/3DJCJ9H
Languageen
Target File32 Automated detection of the left ventricle.pdf
User Groupcintiagraziele.silva@gmail.com
Visibilityshown
5. Allied materials
Mirror Repositorysid.inpe.br/sibgrapi@80/2007/08.02.16.22
Next Higher Units8JMKD3MGPEW34M/4742MCS
8JMKD3MGPBW34M/3DKGHN2
8JMKD3MGPBW34M/3DL29P8
Citing Item Listsid.inpe.br/sibgrapi/2013/02.25.18.00 1
Host Collectionsid.inpe.br/banon/2001/03.30.15.38
6. Notes
Empty Fieldsarchivingpolicy archivist area callnumber contenttype copyholder copyright creatorhistory descriptionlevel dissemination documentstage doi edition electronicmailaddress group issn label lineage mark nextedition notes numberofvolumes orcid organization parameterlist parentrepositories previousedition previouslowerunit progress project readergroup readpermission resumeid rightsholder schedulinginformation secondarydate secondarykey secondarymark secondarytype serieseditor session shorttitle sponsor subject tertiarymark url versiontype volume
7. Description control
e-Mail (login)cintiagraziele.silva@gmail.com
update 


Close